Commercial space,
ready to trade.
Offices, showrooms and retail units, where the structure is rarely the hard part — the handover date, the services capacity and the fit-out tolerances are.
01 — Scope
What the work covers
Structure
RCC or composite frame with the spans and floor loadings the intended use actually needs, not the minimum the drawing allows.
Facade & glazing
Elevation treatment, glazing and shopfronts set out so the line reads true across the whole frontage.
Services capacity
Electrical load, HVAC provision, plumbing and fire services sized for the fit-out that follows, with the routes left reachable.
Fit-out coordination
Working alongside the owner's or tenant's fit-out contractor so two programmes land on one date.
Common & service areas
Entrance, circulation, washrooms, parking and back-of-house — consistently slower than their floor area suggests.
Compliance & handover
Fire and safety provisions in place, services tested, and the documentation handed over at completion.
02 — On site
What decides the outcome
The opening date is the brief
Commercial work is usually tied to a lease or a launch. The programme is built backwards from that date, with float put where it can be afforded.
Leave the services reachable
Ceilings and risers that cannot be opened later turn every small change into demolition. Access is designed in, not discovered.
Tolerances tighten at fit-out
Floor levels and wall lines that pass on a residential job will not take a shopfront or a glazed partition. That standard is set from the first pour.
03 — Standards
Materials and workmanship
Floor loading is a decision, not a default
An office floor, a showroom and a retail unit with storage above do not carry the same load, and the structure is designed to the intended use. Changing that use later is expensive precisely because the frame was sized for something else.
Tolerances that a fit-out can actually work to
Glazed partitions, shopfronts and raised floors need a flatness and a wall line that ordinary residential tolerance will not give. That standard is set at the first pour and maintained through screed and plaster, because it cannot be recovered afterwards.
Facade and glazing, sealed against the direction weather comes from
Glazing to the specified glass type and thickness, with the sealant and gasket detail carried consistently around the frontage. Most facade leaks are joint and detail failures rather than material failures.
Services capacity sized for the fit-out, not the shell
Electrical load, HVAC provision, water and fire services sized for what the tenant will install. A shell that meets its own needs and not theirs pushes the shortfall into the fit-out budget, usually at the worst moment.
Fire and life safety as a build item
Escape routes, fire-rated separations, detection and suppression to the applicable National Building Code provisions and local fire requirements. These carry approval consequences, so they belong in the programme rather than at the end of it.
04 — The choice
Shell and core, or fully fitted.
Where the boundary sits decides the price, the programme and who is waiting for whom. It is worth settling before anything is priced.
| Aspect | Shell and core | Fully fitted |
|---|---|---|
| What is delivered | Structure, facade, common areas and main services brought to a defined point | The same, plus internal finishes and partitioning ready to occupy |
| Who does the fit-out | The owner's or tenant's own contractor, on their own programme | One contractor, one programme, one completion date |
| Coordination risk | Two programmes meeting one opening date; the sequence must be agreed in the contract or both sides wait | Held by one party |
| Services | Capacity provided and routes left reachable; final connections are the fit-out's | Taken through to outlets and tested |
| Flexibility for the tenant | High - they build what they want | Lower, unless their requirements are known before the internal work starts |
| Suits | Space being leased, where the tenant is unknown or wants their own identity | Owner-occupied space, or a tenant already signed with settled requirements |
05 — Sequence
How a commercial job runs.
No week counts here on purpose — on a site the duration is set by size, ground conditions and approvals. What each stage names instead is what governs its length.
Brief, drawings and approvals
Governed by the approval path rather than the design. Plan approval, and fire clearance where the occupancy and height require it, sit on the critical path and are worth mapping before anything else is scheduled.
Structure and envelope
Paced by the frame and then the facade. Facade and glazing decisions made late are among the most common causes of a commercial programme slipping, because nothing downstream can be sealed until they are settled.
Services installation
Set by the capacity the intended use needs and by how early the fit-out requirements are known. Routes left unreachable here turn every later change into demolition.
Fit-out coordination and handover
Driven by the agreed access sequence between the base build and the fit-out contractor. The opening date is the brief, and the programme is built backwards from it with float placed where it can be afforded.
06 — Handover
What you should hold at handover.
- Fire and safety provisions in place and signed off, not pending.
- Services tested to the points the contract defined, with the boundary documented.
- The completion or occupancy certificate the occupancy requires before lawful use.
- A snag list closed against your checklist, with the site records handed over.
07 — Questions
Common questions.
What is a shell-and-core handover?
The building is completed structurally, externally and to its main services, with the internal fit-out left to the owner or tenant. The important part is where exactly the boundary sits - which services are brought to which point, and in what state the floor and walls are left.
Who coordinates between the contractor and the fit-out contractor?
Somebody must, and it should be named in the contract. Two programmes landing on one opening date needs an agreed sequence for access, services connection and shared areas, or both parties wait for each other.
How is a commercial programme built around an opening date?
Backwards from the date, with the fixed points - services energisation, statutory approvals, fit-out access - placed first and float distributed into the activities most likely to slip. A programme built forwards from the start date tends to discover the shortfall too late to act on it.
What approvals affect a commercial building?
Plan approval from the local authority, fire clearance where the occupancy and height require it, and a completion or occupancy certificate before lawful use. The sequence and timing vary by occupancy and should be mapped at the start, because several are on the critical path.
Can a commercial building be extended later?
Only if the foundations and frame were designed for it. Providing for future floors or bays is inexpensive at design stage and very expensive afterwards, so it is a decision worth making deliberately rather than by omission.
What usually delays a commercial project?
Late design decisions on the facade and the services, approvals that were started late, and fit-out access that was assumed rather than agreed. The structure itself is rarely the constraint.
08 — Guides
Guides for this
kind of work.
09 — Also
The other work
we take on.
10 — Enquiry
Tell us about
the project.
Location, rough size and the stage you are at is enough to begin. We will come back with what we would need to quote it properly.